dc.date.issued2020-11-
dc.identifier.citationM. A. Ponce-Camacho, J. A. Lopez-Leyva and L. Casemiro-Oliveira, "Experimental Results from Non-Sub-Wavelength Gold Grating-Coupled Surface Plasmon Resonance using a Monochromatic Signal for Gold/Air Interface as the base for Biosensors," 2020 International Conference on Mechatronics, Electronics and Automotive Engineering (ICMEAE), 2020, pp. 127-130, doi: 10.1109/ICMEAE51770.2020.00029.es_ES
dc.identifier.urihttps://repositorio.cetys.mx/handle/60000/1054-
dc.descriptionIndexación SCOPUSes_ES
dc.description.abstractIn this paper, a gold diffraction grating is used to generate surface Plasmon resonance using a ppolarized monochromatic incident signal (λ = 650 nm) and a dimensional ratio between wavelength and spatial period of metallic grating less than the unit (λ/ d <; 1) for gold/air interface. The surface Plasmon resonance was detected using the angular detection technique. The experimental results show that the resonance angle is ≈15.75° and it is close to the theoretical results calculated (≈15.17°) for the gold diffraction grating. The preliminary results are important for the research and technical development of low-cost biosensors.es_ES
dc.language.isoenes_ES
dc.rightsAtribución-NoComercial-CompartirIgual 2.5 México*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/2.5/mx/*
dc.subjectIntegrated opticses_ES
dc.subjectGoldes_ES
dc.subjectOptical polarizationes_ES
dc.subjectBiomedical optical imagines_ES
dc.titleExperimental results from non-sub-wavelength gold grating-coupled surface plasmon resonance using a monochromatic signal for gold/air interface as the base for biosensorses_ES
dc.typePresentationes_ES
dc.description.urlhttps://ieeexplore.ieee.org/document/9359407/keywords#keywordses_ES
dc.identifier.doihttps://doi.org/10.1109/ICMEAE51770.2020.00029-
dc.subject.sedeCampus Ensenadaes_ES